WEM1ELC series residual current operated circuit breaker

Product number:

Summary Description:

WEM1ELC series residual current operated circuit breaker is suitable for low-voltage power grid system with three-phase four-wire neutral point directly grounded (TT). It is used to protect the grounding fault, overcurrent, short circuit, overvoltage, undervoltage, power failure automatic trip and phase loss of line or electrical equipment, and can also provide indirect contact protection for personal electric shock hazard.

Product Parameters Product Sample Certificate
  • Product Parameters
  • Certificate
    • Commodity name: WEM1ELC series residual current operated circuit breaker

    WEM1ELC series residual current operated circuit breaker is suitable for low-voltage power grid system with three-phase four-wire neutral point directly grounded (TT). It is used to protect the grounding fault, overcurrent, short circuit, overvoltage, undervoltage, power failure automatic trip and phase loss of line or electrical equipment, and can also provide indirect contact protection for personal electric shock hazard.

    Main technical parameters

    Shell frame current:125A、250A、400A、630ARated voltage:400V
    Rated current:40~630ARated insulation voltage:1000V
    Number of poles:3P N, 4PFrequency:50HZ
    Rated ultimate short-circuit breaking capacity (Icu):50~85kARated operating short circuit breaking capacity (Ics):35~65kA
    Rated residual operating current I Δn:50mA/100mA/200mA/300mA/400mA/500mA/800mA/1000mA (grading adjustable)Rated impulse withstand voltage (Uimp):8kV
    Function:Rs485 communication, pluggable lightning protection module, infrared communication, etc.Installation method:L:N pole on the left (left zero);R:N pole on the right (right zero)

     

    Working and installation environment

    Ambient temperature:-5 ℃ ~ 40 ℃, and the average value does not exceed 35 ℃

    Atmospheric conditions:The relative humidity of the atmosphere does not exceed 50% when the surrounding air is +40 ℃, and can have higher relative humidity at lower temperature, such as 90% at 20 ℃; Special measures should be taken for condensation occasionally generated by temperature changes

    Altitude:The elevation of the installation site does not exceed 2000m

    Installation category:III

    Pollution level:Level 3

    Usage category:Class B

    Electromagnetic compatibility:The magnetic field strength of the external magnetic field at the installation site in any direction does not exceed 5 times of the geomagnetic field