  • WEM1E电子式塑壳断路器(修改后白底).png

WEM1E Series Electronic Moulded Case Circuit Breaker

Product number:

Summary Description:

WEM1E series electronic molded case circuit breakers are suitable for infrequent conversion and infrequent starting of motors in circuits with AC 50Hz, rated working voltage of 400V and rated working current of 800A. The circuit breaker has the functions of overload long delay inverse time limit, short circuit short delay inverse time limit, short circuit short delay time limit and short circuit instantaneous protection, which can protect the circuit and power supply equipment from damage. It has the characteristics of small size, high breaking, short arcing and anti-vibration.

Product Parameters Product Sample Certificate
  • Product Parameters
  • Certificate
    • Commodity name: WEM1E Series Electronic Moulded Case Circuit Breaker

    WEM1E series electronic molded case circuit breakers are suitable for infrequent conversion and infrequent starting of motors in circuits with AC 50Hz, rated working voltage of 400V and rated working current of 800A. The circuit breaker has the functions of overload long delay inverse time limit, short circuit short delay inverse time limit, short circuit short delay time limit and short circuit instantaneous protection, which can protect the circuit and power supply equipment from damage. It has the characteristics of small size, high breaking, short arcing and anti-vibration.

    Main technical parameters

    Shell frame current:125A、250A、400A、630A、800ARated voltage:400V/690V
    Rated current:16~800ARated insulation voltage:1000V
    Number of poles:3P、4PFrequency:50HZ
    Rated ultimate short-circuit breaking capacity (Icu):

    50~100kA(400V)

    20~30kA(690V)

    Rated operating short circuit breaking capacity (Ics):

    35~75kA(400V)

    10~20kA(690V)

    Rated short-time withstand current (Icw):

    5~10kA/0.5s(400V)

    5~10kA/0.5s(690V)

    Rated impulse withstand voltage (Uimp):8kV
    Operation mode:Electric/manual/rotating handleInstallation method:Board front wiring, board rear wiring, plug-in board front wiring, plug-in board rear wiring, pull-out type

     

    Working and installation environment

    Ambient temperature:-5 ℃ ~ 40 ℃, and the average value does not exceed 35 ℃

    Atmospheric conditions:The relative humidity of the atmosphere does not exceed 50% at an ambient air temperature of +40°C, and may have a higher relative humidity at lower temperatures, for example up to 90% at 20°C. Special measures should be taken for occasional condensation due to temperature changes.

    Altitude:The elevation of the installation site does not exceed 2000m

    Installation category:The installation category of the main circuit and undervoltage tripping of the circuit breaker is III, and the installation category of the other auxiliary circuits and control circuits is II.

    Pollution level:Level 3

    Protection class:IP30

    Usage category:Class B

Key words:

Explosion-proof monitoring

Online message