  • WEW45智能型万能式断路器(修改后白底).png

WEW45 Series Universal Circuit Breaker

Product number:

Summary Description:

WEW45 series intelligent universal circuit breaker is suitable for distribution network with AC 50HZ, rated voltage to 660V(690V) and rated current of 400A ~ 6300A. It is used to distribute electric energy and protect lines and power supply equipment from overload, undervoltage, short circuit, single-phase grounding and other faults. Circuit breaker with intelligent protection function, selective protection precision, can improve the reliability of power supply, to avoid unnecessary power outages. At the same time, it has an open communication interface, which can carry out "four remotes" to meet the requirements of the control center and automation system. When the circuit breaker is at an altitude of 2000 meters, the pulse withstand voltage is 8000V (different altitudes are corrected according to the standard, and the maximum is not more than 12000V). The circuit breaker can be used as an isolator without intelligent controller and sensor.

Product Parameters Product Sample Certificate
  • Product Parameters
  • Certificate
    • Commodity name: WEW45 Series Universal Circuit Breaker

    WEW45 series intelligent universal circuit breaker is suitable for distribution network with AC 50HZ, rated voltage to 660V(690V) and rated current of 400A ~ 6300A. It is used to distribute electric energy and protect lines and power supply equipment from overload, undervoltage, short circuit, single-phase grounding and other faults. Circuit breaker with intelligent protection function, selective protection precision, can improve the reliability of power supply, to avoid unnecessary power outages. At the same time, it has an open communication interface, which can carry out "four remotes" to meet the requirements of the control center and automation system. When the circuit breaker is at an altitude of 2000 meters, the pulse withstand voltage is 8000V (different altitudes are corrected according to the standard, and the maximum is not more than 12000V). The circuit breaker can be used as an isolator without intelligent controller and sensor.

    Main technical parameters

    Shell frame current:2000~6300ARated voltage:400/690V
    Rated current:400~6300ARated insulation voltage:1000V
    Number of poles:3P、4PFrequency:50HZ
    Rated ultimate short-circuit breaking capacity (Icu):

    80~120kA(400V)、

    80~100kA(690V)

    Rated operating short circuit breaking capacity (Ics):

    65~120kA(400V)、

    65~100kA(690V)

    Rated short-time withstand current (Icw):

    65~120kA/1s(400V)、

    65~100kA/1s(690V)

    Rated impulse withstand voltage (Uimp):12kV
    intelligent controller type:Economic type L, standard type M, communication type HInstallation method:Drawer type, fixed type

     

    Working and installation environment

    Ambient temperature:Ambient air temperature -5 ℃ ~ 40 ℃

    Atmospheric conditions:The relative humidity of the atmosphere does not exceed 50% at an ambient air temperature of +40°C, and may have a higher relative humidity at lower temperatures, for example up to 90% at 20°C. Special measures should be taken for occasional condensation due to temperature changes.

    Altitude:The elevation of the installation site does not exceed 2000m

    Installation category:The main circuit is IV; the other auxiliary circuits and control circuits are III.

    Pollution level:Level 3

    Protection class:IP30

    Installation angle:The vertical inclination angle of the circuit breaker is 5 °

Key words:

Explosion-proof monitoring

Online message

Dear customers, if you have any comments and suggestions on our products or services, please tell us in time, we will give you satisfaction as soon as possible