  • WEL7小型断路器(修改后白底).png

WEL7 Series Miniature Circuit Breaker

Product number:

Classification:

Summary Description:

WEL7 series high breaking miniature circuit breaker, with advanced structure, reliable performance, high breaking capacity, beautiful and small appearance. The shell is made of impact-resistant and high flame-retardant materials, and is suitable for overload and short-circuit protection of lines with AC 50/60Hz, rated voltage 230V/400V and rated current up to 125A. It can also be used for infrequent operation and conversion of lines under normal circumstances. Mainly used in industrial, civil construction, energy and infrastructure and other fields of low-voltage terminal power distribution.

Product Parameters Product Sample Certificate
  • Product Parameters
  • Certificate
    • Commodity name: WEL7 Series Miniature Circuit Breaker

    WEL7 series high breaking miniature circuit breaker, with advanced structure, reliable performance, high breaking capacity, beautiful and small appearance. The shell is made of impact-resistant and high flame-retardant materials, and is suitable for overload and short-circuit protection of lines with AC 50/60Hz, rated voltage 230V/400V and rated current up to 125A. It can also be used for infrequent operation and conversion of lines under normal circumstances. Mainly used in industrial, civil construction, energy and infrastructure and other fields of low-voltage terminal power distribution.

    Main technical parameters

    Shell frame current:63A、125ANumber of poles:1P、2P、3P、4P
    Rated current:6~125AOvercurrent instantaneous trip type:Type B, Type C, Type D
    Rated insulation voltage (Ui):400VRated voltage:230V(1P、2P)、400V (3P、4P)
    Rated short circuit capacity:4.5~6kARated impulse withstand voltage (Uimp):4kV
    Mechanical life:10000 timesElectrical life:6000 times

     

    Working and installation environment

    Ambient temperature:-5 ℃ ~ 40 ℃, and the average value does not exceed 35 ℃

    Atmospheric conditions:The relative humidity of the atmosphere does not exceed 50% at an ambient air temperature of +40°C, and may have a higher relative humidity at lower temperatures, for example up to 90% at 20°C. Special measures should be taken for occasional condensation due to temperature changes.

    Altitude:The elevation of the installation site does not exceed 2000m

    Protection class:IP20

    Pollution level:Level 2

    Electromagnetic compatibility:The external magnetic field at the installation site should not exceed 5 times of the geomagnetic field in any direction.