  • WEGL隔离开关(修改后白底).png

WEGL Series Isolating Switches

Product number:

Classification:

Summary Description:

WEGL series isolating switches are suitable for power distribution equipment of industrial enterprises with AC 50Hz, rated voltage to 660V, DC voltage to 440V and agreed heating current value of 1600A. They are used for infrequent connection and disconnection circuits and electrical isolation. They are widely used in power distribution systems and automation systems in construction, electric power, petrochemical and other industries. The switch is beautiful in appearance, novel and simple, small in size and full in function, which is the best choice for similar products.

Product Parameters Product Sample Certificate
  • Product Parameters
  • Certificate
    • Commodity name: WEGL Series Isolating Switches

    WEGL series isolating switches are suitable for power distribution equipment of industrial enterprises with AC 50Hz, rated voltage to 660V, DC voltage to 440V and agreed heating current value of 1600A. They are used for infrequent connection and disconnection circuits and electrical isolation. They are widely used in power distribution systems and automation systems in construction, electric power, petrochemical and other industries. The switch is beautiful in appearance, novel and simple, small in size and full in function, which is the best choice for similar products.

    Main technical parameters

    Shell frame current:160A、250A、400A、630A、1000A、1600ARated voltage:400V
    Rated current:16~630ARated insulation voltage:1000V
    Number of poles:3P、4PFrequency:50HZ
    Rated short-time withstand current (Icw):10~50kA/1sRated short-circuit make capacity (peak) Icm:12~50kA
    Rated impulse withstand voltage (Uimp):12kVRated impulse withstand voltage (Uimp):12kV
    Operation mode:Front operation, C side operation, Z conversion operationWiring mode:Board front wiring, board rear wiring

     

    Working and installation environment

    Ambient temperature:-5 ℃ ~ 40 ℃, and the average value does not exceed 35 ℃

    Atmospheric conditions:The relative humidity of the atmosphere does not exceed 50% when the ambient air is +40 ℃, and can have higher relative humidity at lower temperatures, such as 90% at 20 ℃.

    Altitude:The elevation of the installation site does not exceed 2000m

    Pollution level:III

    Usage category:AC-23B